5950-01-494-1987, 5950014941987 (Transformer Power) - National Stock Number Lookup

NSN 5950-01-494-1987 of part number 852-00509, 852-00509, 852-00509, FS-2-1500, FS-2-1500, FS-2-1500 by the manufacturer, Acme Electric Corp, Acme Transformer Co, Production Control Units Inc is in stock and ready to ship out. We make NSN parts purchasing as simple as possible. We list corresponding components such as 5950-01-494-1987 so that you can make the purchasing decision that is right for you. Our dedicated team are on hand to help source any-hard-find NSN parts or answer any procurement questions. We only source from manufacturers we trust and are the only independent distributor with a NO CHINA SOURCING policy. Unlike other companies, we pair every customer with a dedicated account manager. We respond to all RFQs within 15 minutes. Submit an RFQ today to get started.

5950-01-494-1987 NSN Information

Alternative NSN: 5950-01-494-1987
Item Name: Transformer Power
FSG: 59 Electrical and Electronic Equipment Components
Federal Supply Class (FSC): 5950 Coils and Transformers
NIIN: 014941987
NCB Code: USA (01)
Manufacturers: Acme Electric Corp, Acme Transformer Co, Production Control Units Inc

NSN 5950-01-494-1987 Manufacturing Part Numbers

Part No Manufacturer Item Name QTY RFQ
852-00509 acme transformer co transformer power Avl RFQ
852-00509 acme electric corp transformer power Avl RFQ
852-00509 production control units inc transformer power Avl RFQ
FS-2-1500 acme transformer co transformer power Avl RFQ
FS-2-1500 acme electric corp transformer power Avl RFQ
FS-2-1500 production control units inc transformer power Avl RFQ

Product Specification of NSN 5950014941987

MRCCriteriaCharacteristic
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH5.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH4.130 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
AXGYMOUNTING METHODSLOT SINGLE GROUP
AKNAINCLOSURE TYPEFULLY INCLOSED
AGAVIII END ITEM IDENTIFICATIONAIRCRAFT, B-2 BOMBER (ATB)
AKPVMOUNTING FACILITY QUANTITY4 SINGLE GROUP
CRBZWINDING OPERATING CURRENT12.50 AMPERES AC MINIMUM AND 13.63 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
AARGRELIABILITY INDICATORNOT ESTABLISHED
ABKWOVERALL HEIGHT6.030 INCHES NOMINAL
ABMKOVERALL WIDTH6.010 INCHES NOMINAL
ABTDMOUNTING SLOT WIDTH0.310 INCHES MINIMUM AND 0.500 INCHES MAXIMUM SINGLE GROUP
CWJSWINDING OPERATING VOLTAGE220.00 AC VOLTS NOMINAL AND 230.00 AC VOLTS NOMINAL AND 240.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY 440.00 AC VOLTS NOMINAL AND 460.00 AC VOLTS NOMINAL AND 480.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY 110.00 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL AND 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
ABHPOVERALL LENGTH6.750 INCHES NOMINAL
ACZBFREQUENCY RATING50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL SINGLE COMPONENT
TTQYTERMINAL TYPE AND QUANTITY6 COMPRESSION
ACZCINPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT