5950-01-138-1881, 5950011381881 (Transformer Power) - National Stock Number Lookup

NSN 5950-01-138-1881 of part number 905876-1, 905876-1, 905876-1, 13137, 13137, 13137, 03835, 03835 by the manufacturer, Dbp Microwave Inc, Magnespec Inc, Magnetika Inc, Robert M Hadley Company Inc is in stock and ready to ship out. We make NSN parts purchasing as simple as possible. We list corresponding components such as 5950-01-138-1881 so that you can make the purchasing decision that is right for you. Our dedicated team are on hand to help source any-hard-find NSN parts or answer any procurement questions. We only source from manufacturers we trust and are the only independent distributor with a NO CHINA SOURCING policy. Unlike other companies, we pair every customer with a dedicated account manager. We respond to all RFQs within 15 minutes. Submit an RFQ today to get started.

5950-01-138-1881 NSN Information

Alternative NSN: 5950-01-138-1881
Item Name: Transformer Power
FSG: 59 Electrical and Electronic Equipment Components
Federal Supply Class (FSC): 5950 Coils and Transformers
NIIN: 011381881
NCB Code: USA (01)
Manufacturers: Dbp Microwave Inc, Magnespec Inc, Magnetika Inc, Robert M Hadley Company Inc

NSN 5950-01-138-1881 Manufacturing Part Numbers

Part No Manufacturer Item Name QTY RFQ
905876-1 robert m hadley company inc transformer power Avl RFQ
905876-1 magnetika inc transformer power Avl RFQ
905876-1 dbp microwave inc transformer power Avl RFQ
13137 magnespec inc transformer power Avl RFQ
13137 magnetika inc transformer power Avl RFQ
13137 dbp microwave inc transformer power Avl RFQ
03835 dbp microwave inc transformer power Avl RFQ
03835 magnetika inc transformer power Avl RFQ

Product Specification of NSN 5950011381881

MRCCriteriaCharacteristic
AARGRELIABILITY INDICATORNOT ESTABLISHED
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.710 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.730 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.710 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.730 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ACZBFREQUENCY RATING17.0 KILOHERTZ MINIMUM SINGLE COMPONENT AND 35.0 KILOHERTZ MAXIMUM SINGLE COMPONENT
ACZCINPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
ADAQBODY LENGTH2.110 INCHES MINIMUM AND 2.130 INCHES MAXIMUM
ADATBODY WIDTH2.110 INCHES MINIMUM AND 2.130 INCHES MAXIMUM
ADAUBODY HEIGHT1.060 INCHES MAXIMUM
AEHZMAXIMUM OPERATING TEMP130.0 DEG CELSIUS
AKNAINCLOSURE TYPEFULLY INCLOSED
AKPVMOUNTING FACILITY QUANTITY4 SINGLE GROUP
AXGYMOUNTING METHODTHREADED HOLE SINGLE GROUP
BPLCWINDING FUNCTION AND QUANTITY1 PRIMARY SINGLE COMPONENT AND 8 SECONDARY SINGLE COMPONENT
CQJXNOMINAL THREAD SIZE0.138 INCHES SINGLE GROUP
CRBZWINDING OPERATING CURRENT2.6 AMPERES DC MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 3.8 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
CRBZWINDING OPERATING CURRENT200.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 4TH SECONDARY
CRBZWINDING OPERATING CURRENT250.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY
CRBZWINDING OPERATING CURRENT750.0 MILLIAMPERES DC MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 1.5 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
CWJSWINDING OPERATING VOLTAGE112.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
CWJSWINDING OPERATING VOLTAGE20.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
CWJSWINDING OPERATING VOLTAGE32.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
CWJSWINDING OPERATING VOLTAGE42.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
CWJSWINDING OPERATING VOLTAGE58.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
FEATSPECIAL FEATURESONE PRIMARY WINDING; EIGHT SECONDARY WINDINGS,FIRST,SECOND,THIRD,FOURTH,FIFTH,AND SIXTH SECONDARY CENTER TAPPED
THSDTHREAD SERIES DESIGNATORUNC SINGLE GROUP
TTQYTERMINAL TYPE AND QUANTITY25 TURRET