5950-01-056-7673, 5950010567673 (Transformer Power) - National Stock Number Lookup

NSN 5950-01-056-7673 of part number C104950 by the manufacturer, Integrated Power Systems Inc is in stock and ready to ship out. We make NSN parts purchasing as simple as possible. We list corresponding components such as 5950-01-056-7673 so that you can make the purchasing decision that is right for you. Our dedicated team are on hand to help source any-hard-find NSN parts or answer any procurement questions. We only source from manufacturers we trust and are the only independent distributor with a NO CHINA SOURCING policy. Unlike other companies, we pair every customer with a dedicated account manager. We respond to all RFQs within 15 minutes. Submit an RFQ today to get started.

5950-01-056-7673 NSN Information

Alternative NSN: 5950-01-056-7673
Item Name: Transformer Power
FSG: 59 Electrical and Electronic Equipment Components
Federal Supply Class (FSC): 5950 Coils and Transformers
NIIN: 010567673
NCB Code: USA (01)
Manufacturers: Integrated Power Systems Inc

NSN 5950-01-056-7673 Manufacturing Part Numbers

Part No Manufacturer Item Name QTY RFQ
C104950 integrated power systems inc transformer power Avl RFQ

Product Specification of NSN 5950010567673

MRCCriteriaCharacteristic
AARGRELIABILITY INDICATORNOT ESTABLISHED
ABTBMOUNTING HOLE DIAMETER0.140 INCHES NOMINAL SINGLE GROUP
ACZBFREQUENCY RATING10.0 KILOHERTZ NOMINAL SINGLE COMPONENT
ACZCINPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
AKNAINCLOSURE TYPEFULLY INCLOSED
AKPVMOUNTING FACILITY QUANTITY1 SINGLE GROUP
AXGYMOUNTING METHODUNTHREADED HOLE SINGLE GROUP
BPLCWINDING FUNCTION AND QUANTITY2 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT
CRBZWINDING OPERATING CURRENT5.4 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
CRBZWINDING OPERATING CURRENT600.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
CRBZWINDING OPERATING CURRENT7.2 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
CRBZWINDING OPERATING CURRENT700.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST PRIMARY
CWJSWINDING OPERATING VOLTAGE42.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
CWJSWINDING OPERATING VOLTAGE42.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
CWJSWINDING OPERATING VOLTAGE48.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY
CWJSWINDING OPERATING VOLTAGE50.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
CWJSWINDING OPERATING VOLTAGE56.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY
TTQYTERMINAL TYPE AND QUANTITY15 TURRET