5925-01-363-6284, 5925013636284 (Circuit Breaker) - National Stock Number Lookup

NSN 5925-01-363-6284 of part number 412-K14-LN2, 41 2 S14 LN2 by the manufacturer, Oakland Industries Ltd is in stock and ready to ship out. We make NSN parts purchasing as simple as possible. We list corresponding components such as 5925-01-363-6284 so that you can make the purchasing decision that is right for you. Our dedicated team are on hand to help source any-hard-find NSN parts or answer any procurement questions. We only source from manufacturers we trust and are the only independent distributor with a NO CHINA SOURCING policy. Unlike other companies, we pair every customer with a dedicated account manager. We respond to all RFQs within 15 minutes. Submit an RFQ today to get started.

5925-01-363-6284 NSN Information

Alternative NSN: 5925-01-363-6284
Item Name: Circuit Breaker
FSG: 59 Electrical and Electronic Equipment Components
Federal Supply Class (FSC): 5925 Circuit Breakers
NIIN: 013636284
NCB Code: USA (01)
Manufacturers: Oakland Industries Ltd

NSN 5925-01-363-6284 Manufacturing Part Numbers

Part No Manufacturer Item Name QTY RFQ
412-K14-LN2 oakland industries ltd circuit breaker Avl RFQ
41 2 S14 LN2 oakland industries ltd circuit breaker Avl RFQ

Product Specification of NSN 5925013636284

MRCCriteriaCharacteristic
AAQLBODY STYLERECTANGULAR DIMENSIONAL ENVELOPE
ABHPOVERALL LENGTH2.300 INCHES NOMINAL
ABKWOVERALL HEIGHT0.570 INCHES NOMINAL
ABMKOVERALL WIDTH1.140 INCHES NOMINAL
ADTVCASE MATERIALPLASTIC
AKPXPOLE QUANTITY1
AXHRMOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE5.0 AMPERES AC SINGLE LOCATION AND 5.0 AMPERES DC SINGLE LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS115.0 AC SINGLE LOCATION AND 28.0 DC SINGLE LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1500.0 AC SINGLE LOCATION AND 1500.0 DC SINGLE LOCATION
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION
CPRJTRIP RELEASE METHODMAGNETIC SINGLE LOCATION
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
FREQFREQUENCY IN HERTZ60.0 SINGLE LOCATION
THSDTHREAD SERIES DESIGNATORUNC
TTQYTERMINAL TYPE AND QUANTITY2 TAB W/SCREW
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 SINGLE LOCATION
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY SINGLE LOCATION
CPRQRESET METHODMANUAL
CPRTMANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SINGLE LOCATION
CQJXNOMINAL THREAD SIZE0.164 INCHES
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT20.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 70.000 MAXIMUM AT 200 PCT SINGLE LOCATION