5925-01-254-4779, 5925012544779 (Circuit Breaker) - National Stock Number Lookup

NSN 5925-01-254-4779 of part number JE1 V3 A 5 3, 9291654-1 by the manufacturer, Eaton Corporation is in stock and ready to ship out. We make NSN parts purchasing as simple as possible. We list corresponding components such as 5925-01-254-4779 so that you can make the purchasing decision that is right for you. Our dedicated team are on hand to help source any-hard-find NSN parts or answer any procurement questions. We only source from manufacturers we trust and are the only independent distributor with a NO CHINA SOURCING policy. Unlike other companies, we pair every customer with a dedicated account manager. We respond to all RFQs within 15 minutes. Submit an RFQ today to get started.

5925-01-254-4779 NSN Information

Alternative NSN: 5925-01-254-4779
Item Name: Circuit Breaker
FSG: 59 Electrical and Electronic Equipment Components
Federal Supply Class (FSC): 5925 Circuit Breakers
NIIN: 012544779
NCB Code: USA (01)
Manufacturers: Eaton Corporation

NSN 5925-01-254-4779 Manufacturing Part Numbers

Part No Manufacturer Item Name QTY RFQ
JE1 V3 A 5 3 eaton corporation circuit breaker Avl RFQ
9291654-1 eaton corporation circuit breaker Avl RFQ

Product Specification of NSN 5925012544779

MRCCriteriaCharacteristic
AAQLBODY STYLESINGLE POLE TYPE
ABXDBUSHING LENGTH0.344 INCHES MINIMUM AND 0.406 INCHES MAXIMUM
ADAQBODY LENGTH1.969 INCHES MINIMUM AND 2.031 INCHES MAXIMUM
ADATBODY WIDTH0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM
ADTVCASE MATERIALPLASTIC
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.529 INCHES MINIMUM AND 1.591 INCHES MAXIMUM
AFJNFRAGILITY FACTORMODERATELY RUGGED
AGAVEND ITEM IDENTIFICATION1095-00-397-3456
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE2.094 INCHES MINIMUM AND 2.156 INCHES MAXIMUM
AKPXPOLE QUANTITY1
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE5.0 AMPERES DC SINGLE LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS32.0 DC SINGLE LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1000.0 DC SINGLE LOCATION
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC SINGLE LOCATION
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY SINGLE LOCATION
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 SINGLE LOCATION
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SINGLE LOCATION
CQJXNOMINAL THREAD SIZE0.375 INCHES
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT0.150 MINIMUM AT 200 PCT SINGLE LOCATION AND 1.400 MAXIMUM AT 200 PCT SINGLE LOCATION
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTPROOF
THSDTHREAD SERIES DESIGNATORUNEF
TTQYTERMINAL TYPE AND QUANTITY2 TAB W/SCREW