5925-01-186-6343, 5925011866343 (Circuit Breaker) - National Stock Number Lookup

NSN 5925-01-186-6343 of part number UPGX1-1-62-303-91, UPGX1-1-62-303-91, JC1-A3-JB-A-30-2, JC1-A3-JB-A-30-2, JC1-A3-JB-A-30-2, 567612-3, 567612-3, 567612 3 by the manufacturer, Eaton Corporation, Raytheon Company, Raytheon Technical Services Company, Sensata Technologies Inc is in stock and ready to ship out. We make NSN parts purchasing as simple as possible. We list corresponding components such as 5925-01-186-6343 so that you can make the purchasing decision that is right for you. Our dedicated team are on hand to help source any-hard-find NSN parts or answer any procurement questions. We only source from manufacturers we trust and are the only independent distributor with a NO CHINA SOURCING policy. Unlike other companies, we pair every customer with a dedicated account manager. We respond to all RFQs within 15 minutes. Submit an RFQ today to get started.

5925-01-186-6343 NSN Information

Alternative NSN: 5925-01-186-6343
Item Name: Circuit Breaker
FSG: 59 Electrical and Electronic Equipment Components
Federal Supply Class (FSC): 5925 Circuit Breakers
NIIN: 011866343
NCB Code: USA (01)
Manufacturers: Eaton Corporation, Raytheon Company, Raytheon Technical Services Company, Sensata Technologies Inc

NSN 5925-01-186-6343 Manufacturing Part Numbers

Part No Manufacturer Item Name QTY RFQ
UPGX1-1-62-303-91 sensata technologies inc circuit breaker Avl RFQ
UPGX1-1-62-303-91 raytheon company circuit breaker Avl RFQ
JC1-A3-JB-A-30-2 sensata technologies inc circuit breaker Avl RFQ
JC1-A3-JB-A-30-2 raytheon company circuit breaker Avl RFQ
JC1-A3-JB-A-30-2 eaton corporation circuit breaker Avl RFQ
567612-3 raytheon technical services company circuit breaker Avl RFQ
567612-3 sensata technologies inc circuit breaker Avl RFQ
567612 3 raytheon company circuit breaker Avl RFQ

Product Specification of NSN 5925011866343

MRCCriteriaCharacteristic
AAQLBODY STYLESINGLE POLE TYPE
ADAQBODY LENGTH2.000 INCHES NOMINAL
ADATBODY WIDTH0.750 INCHES NOMINAL
ADTVCASE MATERIALPLASTIC
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.530 INCHES NOMINAL
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.660 INCHES NOMINAL
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE2.422 INCHES MAXIMUM
AKPXPOLE QUANTITY1
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
BBRJSPECIAL HANDLING FEATUREMAGNETIC
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE30.0 AMPERES AC SINGLE LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC SINGLE LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS5000.0 AC SINGLE LOCATION
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC SINGLE LOCATION
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY SINGLE LOCATION
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 SINGLE LOCATION
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
CPSMINTERNAL TRIP RELEASE CONFIGURATIONRELAY TRIP SINGLE LOCATION
CQJXNOMINAL THREAD SIZE0.138 INCHES
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT2.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND MOISTURE RESISTANT
FREQFREQUENCY IN HERTZ50.0 SINGLE LOCATION OR 60.0 SINGLE LOCATION
PKWTUNPACKAGED UNIT WEIGHT2.500 OUNCES
THSDTHREAD SERIES DESIGNATORUNC
TTQYTERMINAL TYPE AND QUANTITY2 QUICK DISCONNECT, MALE

NSN 5925-01-186-6343 - Similar National Stock Numbers

Get an Estimate for Your Required Component

You will receive a response in 15 minutes or less









Install ASAP App for Quick Actions