5925-00-759-0906, 5925007590906 (Circuit Breaker) - National Stock Number Lookup

NSN 5925-00-759-0906 of part number SM33-5DC2, HM2 B3 5 50DC 2, HE2-B3-5-50DC-2 by the manufacturer, Eaton Corporation is in stock and ready to ship out. We make NSN parts purchasing as simple as possible. We list corresponding components such as 5925-00-759-0906 so that you can make the purchasing decision that is right for you. Our dedicated team are on hand to help source any-hard-find NSN parts or answer any procurement questions. We only source from manufacturers we trust and are the only independent distributor with a NO CHINA SOURCING policy. Unlike other companies, we pair every customer with a dedicated account manager. We respond to all RFQs within 15 minutes. Submit an RFQ today to get started.

5925-00-759-0906 NSN Information

Alternative NSN: 5925-00-759-0906
Item Name: Circuit Breaker
FSG: 59 Electrical and Electronic Equipment Components
Federal Supply Class (FSC): 5925 Circuit Breakers
NIIN: 007590906
NCB Code: USA (00)
Manufacturers: Eaton Corporation

NSN 5925-00-759-0906 Manufacturing Part Numbers

Part No Manufacturer Item Name QTY RFQ
SM33-5DC2 eaton corporation circuit breaker Avl RFQ
HM2 B3 5 50DC 2 eaton corporation circuit breaker Avl RFQ
HE2-B3-5-50DC-2 eaton corporation circuit breaker Avl RFQ

Product Specification of NSN 5925007590906

MRCCriteriaCharacteristic
AAQLBODY STYLEMULTIPOLE-SINGLE ACTUATOR TYPE
ABXDBUSHING LENGTH0.365 INCHES MINIMUM AND 0.385 INCHES MAXIMUM
ADAQBODY LENGTH1.552 INCHES MINIMUM AND 1.572 INCHES MAXIMUM
ADATBODY WIDTH1.271 INCHES MINIMUM AND 1.291 INCHES MAXIMUM
ADTVCASE MATERIALMETAL
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.865 INCHES MINIMUM AND 0.885 INCHES MAXIMUM
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.615 INCHES MINIMUM AND 0.635 INCHES MAXIMUM
AFJNFRAGILITY FACTORMODERATELY RUGGED
AKPXPOLE QUANTITY2
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING W/PANEL SEAL
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE5.0 AMPERES DC ALL LOCATIONS
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS
CQJXNOMINAL THREAD SIZE0.375 INCHES
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT0.120 MINIMUM AT 200 PCT ALL LOCATIONS AND 0.750 MAXIMUM AT 200 PCT ALL LOCATIONS
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDHERMETICALLY SEALED
THSDTHREAD SERIES DESIGNATORUNEF
TTQYTERMINAL TYPE AND QUANTITY4 WIRE HOOK
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE1.690 INCHES MINIMUM AND 1.710 INCHES MAXIMUM
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS50.0 DC ALL LOCATIONS
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS500.0 DC ALL LOCATIONS
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE