NSN 5925-00-153-6426 of part number TE122010WLUV1RS, TEB122010WLUV1RS by the manufacturer, General Electric Co is in stock and ready to ship out. We make NSN parts purchasing as simple as possible. We list corresponding components such as 5925-00-153-6426 so that you can make the purchasing decision that is right for you. Our dedicated team are on hand to help source any-hard-find NSN parts or answer any procurement questions. We only source from manufacturers we trust and are the only independent distributor with a NO CHINA SOURCING policy. Unlike other companies, we pair every customer with a dedicated account manager. We respond to all RFQs within 15 minutes. Submit an RFQ today to get started.

5925-00-153-6426 NSN Information

Alternative NSN: 5925-00-153-6426
Item Name: Circuit Breaker
FSG: 59 Electrical and Electronic Equipment Components
Federal Supply Class (FSC): 5925 Circuit Breakers
NIIN: 001536426
NCB Code: USA (00)
Manufacturers: General Electric Co

NSN 5925-00-153-6426 Manufacturing Part Numbers

Part No Manufacturer Item Name QTY RFQ
TE122010WLUV1RS general electric co circuit breaker Avl RFQ
TEB122010WLUV1RS general electric co circuit breaker Avl RFQ

Product Specification of NSN 5925001536426

MRCCriteriaCharacteristic
AAQLBODY STYLERECTANGULAR DIMENSIONAL ENVELOPE
ABHPOVERALL LENGTH6.312 INCHES NOMINAL
ABKWOVERALL HEIGHT4.094 INCHES MAXIMUM
ABMKOVERALL WIDTH2.750 INCHES NOMINAL
ADTVCASE MATERIALPLASTIC
AEBVUNTHREADED MOUNTING HOLE DIAMETER0.203 INCHES NOMINAL
AKPXPOLE QUANTITY2
AXHRMOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE10.0 AMPERES AC ALL LOCATIONS AND 10.0 AMPERES DC ALL LOCATIONS
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC FIRST LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS250.0 DC SECOND LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS10000.0 AC FIRST LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS5000.0 DC SECOND LOCATION
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT FIRST LOCATION
CPRHCIRCUIT PROTECTION TYPEUNDERVOLTAGE SECOND LOCATION
CPRJTRIP RELEASE METHODTHERMAL-MAGNETIC ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT135.0 ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONBETWEEN POLE ONE AND TWO
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT70.000 MINIMUM AT 125 PCT ALL LOCATIONS AND 450.000 MAXIMUM AT 125 PCT ALL LOCATIONS
CRCFTRIP RELEASE AMBIENT TEMP RATING40.0 DEG CELSIUS MAXIMUM ALL LOCATIONS
FREQFREQUENCY IN HERTZ60.0 ALL LOCATIONS
TTQYTERMINAL TYPE AND QUANTITY4 SCREW AND 2 WIRE LEAD