5925-00-109-1765, 5925001091765 (Circuit Breaker) - National Stock Number Lookup

NSN 5925-00-109-1765 of part number PLM120, PLM120, MCM2520, MCM2520 by the manufacturer, General Electric Co, Sensata Technologies Inc is in stock and ready to ship out. We make NSN parts purchasing as simple as possible. We list corresponding components such as 5925-00-109-1765 so that you can make the purchasing decision that is right for you. Our dedicated team are on hand to help source any-hard-find NSN parts or answer any procurement questions. We only source from manufacturers we trust and are the only independent distributor with a NO CHINA SOURCING policy. Unlike other companies, we pair every customer with a dedicated account manager. We respond to all RFQs within 15 minutes. Submit an RFQ today to get started.

5925-00-109-1765 NSN Information

Alternative NSN: 5925-00-109-1765
Item Name: Circuit Breaker
FSG: 59 Electrical and Electronic Equipment Components
Federal Supply Class (FSC): 5925 Circuit Breakers
NIIN: 001091765
NCB Code: USA (00)
Manufacturers: General Electric Co, Sensata Technologies Inc

NSN 5925-00-109-1765 Manufacturing Part Numbers

Part No Manufacturer Item Name QTY RFQ
PLM120 sensata technologies inc circuit breaker Avl RFQ
PLM120 general electric co circuit breaker Avl RFQ
MCM2520 sensata technologies inc circuit breaker Avl RFQ
MCM2520 general electric co circuit breaker Avl RFQ

Product Specification of NSN 5925001091765

MRCCriteriaCharacteristic
AAQLBODY STYLESINGLE POLE TYPE
ABHPOVERALL LENGTH3.156 INCHES NOMINAL
ADATBODY WIDTH1.875 INCHES NOMINAL
ADTVCASE MATERIALPLASTIC
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.062 INCHES NOMINAL
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.406 INCHES NOMINAL
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE1.406 INCHES NOMINAL
AKPXPOLE QUANTITY1
AXHRMOUNTING FACILITY TYPE AND QUANTITY2 THREADED BUSHING
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE120.0 AMPERES AC SINGLE LOCATION AND 120.0 AMPERES DC SINGLE LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS30.0 AC SINGLE LOCATION AND 30.0 DC SINGLE LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS2400.0 AC SINGLE LOCATION AND 2400.0 DC SINGLE LOCATION
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION
CPRJTRIP RELEASE METHODTHERMAL SINGLE LOCATION
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY SINGLE LOCATION
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 SINGLE LOCATION
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY1 PUSH BUTTON
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SINGLE LOCATION
CQJXNOMINAL THREAD SIZE0.190 INCHES
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT8.700 NOMINAL AT 200 PCT SINGLE LOCATION
CRCFTRIP RELEASE AMBIENT TEMP RATING25.0 DEG CELSIUS MAXIMUM SINGLE LOCATION
THSDTHREAD SERIES DESIGNATORUNF
TTQYTERMINAL TYPE AND QUANTITY2 SCREW

NSN 5925-00-109-1765 - Similar National Stock Numbers

Get an Estimate for Your Required Component

You will receive a response in 15 minutes or less









Install ASAP App for Quick Actions