5915-01-334-4791, 5915013344791 (Filter Band Suppres) - National Stock Number Lookup

NSN 5915-01-334-4791 of part number 401004, 1185AS156-1 by the manufacturer, Henderson H F Industries is in stock and ready to ship out. We make NSN parts purchasing as simple as possible. We list corresponding components such as 5915-01-334-4791 so that you can make the purchasing decision that is right for you. Our dedicated team are on hand to help source any-hard-find NSN parts or answer any procurement questions. We only source from manufacturers we trust and are the only independent distributor with a NO CHINA SOURCING policy. Unlike other companies, we pair every customer with a dedicated account manager. We respond to all RFQs within 15 minutes. Submit an RFQ today to get started.

5915-01-334-4791 NSN Information

Alternative NSN: 5915-01-334-4791
Item Name: Filter Band Suppres
FSG: 59 Electrical and Electronic Equipment Components
Federal Supply Class (FSC): 5915 Filters and Networks
NIIN: 013344791
NCB Code: USA (01)
Manufacturers: Henderson H F Industries

NSN 5915-01-334-4791 Manufacturing Part Numbers

Part No Manufacturer Item Name QTY RFQ
401004 henderson h f industries filter band suppres Avl RFQ
1185AS156-1 henderson h f industries filter band suppres Avl RFQ

Product Specification of NSN 5915013344791

MRCCriteriaCharacteristic
ADAQBODY LENGTH8.000 INCHES NOMINAL
ADATBODY WIDTH6.000 INCHES NOMINAL
ADAUBODY HEIGHT3.500 INCHES NOMINAL
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH6.500 INCHES NOMINAL
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH5.500 INCHES NOMINAL
AFGAOPERATING TEMP RANGE-55.0/+85.0 DEG CELSIUS
AHAJREFERENCE FREQUENCY PER FUNCTION175.0 2ND RADIO INTERFERENCE TWO PHASE TO THREE PHASE
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND BAND SUPPRESSION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD BAND SUPPRESSION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD BAND SUPPRESSION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST BAND SUPPRESSION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND BAND SUPPRESSION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD BAND SUPPRESSION
AXHRMOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY3 SCREW INPUT 1ST FUNCTION
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY3 SCREW OUTPUT 2ND FUNCTION
CQFCSPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION100.00 KILOHERTZ 1ST BAND SUPPRESSION AND 150.00 KILOHERTZ 1ST BAND SUPPRESSION AND 200.00 KILOHERTZ 1ST BAND SUPPRESSION AND 250.00 KILOHERTZ 1ST BAND SUPPRESSION
CQFCSPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION100.00 KILOHERTZ 3RD BAND SUPPRESSION AND 150.00 KILOHERTZ 3RD BAND SUPPRESSION AND 200.00 KILOHERTZ 3RD BAND SUPPRESSION AND 250.00 KILOHERTZ 3RD BAND SUPPRESSION
CQRGBODY MATERIALMETAL
CRBBFREQUENCY BAND WIDTH PER FUNCTION150.00 KILOHERTZ 1ST BAND SUPPRESSION AND 200.00 KILOHERTZ 1ST BAND SUPPRESSION
CRBBFREQUENCY BAND WIDTH PER FUNCTION150.00 KILOHERTZ 2ND BAND SUPPRESSION AND 200.00 KILOHERTZ 2ND BAND SUPPRESSION
CRBBFREQUENCY BAND WIDTH PER FUNCTION150.00 KILOHERTZ 3RD BAND SUPPRESSION AND 200.00 KILOHERTZ 3RD BAND SUPPRESSION
CRBCDISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM 1ST BAND SUPPRESSION AND 60.0 MAXIMUM 1ST BAND SUPPRESSION
CRBCDISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM 2ND BAND SUPPRESSION AND 60.0 MAXIMUM 2ND BAND SUPPRESSION
CRBCDISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM 3RD BAND SUPPRESSION AND 60.0 MAXIMUM 3RD BAND SUPPRESSION
FEATSPECIAL FEATURESTHREE FILTERED FUNCTIONS; ONE UNFILTERED FUNCTION
STYLSTYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
ZZZKSPECIFICATION/STANDARD DATA30003-1185AS156 MANUFACTURERS SPECIFICATION CONTROL
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND BAND SUPPRESSION
ABHPOVERALL LENGTH8.000 INCHES NOMINAL
AEBVUNTHREADED MOUNTING HOLE DIAMETER0.172 INCHES NOMINAL
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST BAND SUPPRESSION
AKNAINCLOSURE TYPEENCASED
CQDRINSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 1ST BAND SUPPRESSION
CQDRINSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 2ND BAND SUPPRESSION
CQDRINSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 3RD BAND SUPPRESSION
CQFCSPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION100.00 KILOHERTZ 2ND BAND SUPPRESSION AND 150.00 KILOHERTZ 2ND BAND SUPPRESSION AND 200.00 KILOHERTZ 2ND BAND SUPPRESSION AND 250.00 KILOHERTZ 2ND BAND SUPPRESSION
AHAJREFERENCE FREQUENCY PER FUNCTION175.0 2ND RADIO INTERFERENCE PULSES PER SECOND
AHAJREFERENCE FREQUENCY PER FUNCTION175.0 2ND RADIO INTERFERENCE TWO PHASE TO TWO PHASE
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST BAND SUPPRESSION

NSN 5915-01-334-4791 - Similar National Stock Numbers

Get an Estimate for Your Required Component

You will receive a response in 15 minutes or less









Install ASAP App for Quick Actions