5915-00-228-5778, 5915002285778 (Filter Radio Freque) - National Stock Number Lookup
NSN 5915-00-228-5778 of part number SM-D-63334-3, SM-D-63334-3, S112744-1, S112744 1, F20296, F20296, F20296, 10B497, 10B497 by the manufacturer, Marathonnorco Aerospace Inc, Sfe Technologies, Sora Power Inc is in stock and ready to ship out. We make NSN parts purchasing as simple as possible. We list corresponding components such as 5915-00-228-5778 so that you can make the purchasing decision that is right for you. Our dedicated team are on hand to help source any-hard-find NSN parts or answer any procurement questions. We only source from manufacturers we trust and are the only independent distributor with a NO CHINA SOURCING policy. Unlike other companies, we pair every customer with a dedicated account manager. We respond to all RFQs within 15 minutes. Submit an RFQ today to get started.
5915-00-228-5778 NSN Information
Alternative NSN: 5915-00-228-5778 |
Item Name: Filter Radio Freque |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5915 Filters and Networks |
NIIN: 002285778 |
NCB Code: USA (00) |
Manufacturers: Marathonnorco Aerospace Inc, Sfe Technologies, Sora Power Inc |
NSN 5915-00-228-5778 Manufacturing Part Numbers
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
SM-D-63334-3 | sora power inc | filter radio freque | Avl | RFQ |
SM-D-63334-3 | marathonnorco aerospace inc | filter radio freque | Avl | RFQ |
S112744-1 | sora power inc | filter radio freque | Avl | RFQ |
S112744 1 | marathonnorco aerospace inc | filter radio freque | Avl | RFQ |
F20296 | sora power inc | filter radio freque | Avl | RFQ |
F20296 | sfe technologies | filter radio freque | Avl | RFQ |
F20296 | marathonnorco aerospace inc | filter radio freque | Avl | RFQ |
10B497 | marathonnorco aerospace inc | filter radio freque | Avl | RFQ |
10B497 | sora power inc | filter radio freque | Avl | RFQ |
Product Specification of NSN 5915002285778
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 6.500 INCHES NOMINAL |
ADAQ | BODY LENGTH | 5.000 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.125 INCHES NOMINAL |
ADAU | BODY HEIGHT | 3.500 INCHES MAXIMUM |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.250 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 4.000 INCHES NOMINAL |
AFGA | III OPERATING TEMP RANGE | -60.0 TO 85.0 DEG CELSIUS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 1ST RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 2ND RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 25.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 25.0 4TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 50.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 50.0 2ND RADIO INTERFERENCE |
AHBL | III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | CAPACITANCE-INDUCTANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBL | III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | CAPACITANCE-INDUCTANCE 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | CAPACITANCE-INDUCTANCE 2ND RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | CAPACITANCE-INDUCTANCE 3RD RADIO INTERFERENCE |
AKNA | INCLOSURE TYPE | ENCASED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 THREADED STUD INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 THREADED STUD OUTPUT 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 20.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 20.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 230.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 230.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQRG | BODY MATERIAL | METAL |
CRDC | III MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 500.0 VOLTS AT SEA LEVEL |
CRST | BODY SURFACE TREATMENT | TIN |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
NSN 5915-00-228-5778 - Similar National Stock Numbers
Prominent NSN Parts Brands
- Navistar Canada Inc
- Textron Marine Systems
- Glastic Corp
- C And B Mfg Co
- Moller A P
- Glamox Canada Inc
- Cool Options Inc
- Insultab Inc
- Minco Products Inc
- M B Electronique
- Penn Meter Co
- Ford Werke Gmbh
- Royal Products Inc
- Vetus Llc
- Barry Industries Inc
- Ford Werke Gmbh
- Hart Scientific Llc
- Unimac Corp
- Interphase Inc
- Zamzow Manufacturing Company
- View More
Highly Demanding NSN Components
- Flag Helicopter
- Pump Hauldown
- parts kit test set
- Ferrule Wind Gage
- insert bushing airc
- Stop Droop
- Pump Air Driven
- Operators Panel
- Seal Ring Canopy
- Extracor Card