913-0044-000 (NSN 5910-00-356-0075, 5910003560075) NSN Information
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5910-00-356-0075 Item Description: Capacitor Fixed Cer | 5910 | 003560075 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
913-0044-000 | 3 | 2 | 3 |
NSN 5910-00-356-0075, 5910003560075 Characteristic Data
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | W/O MTG FACILITIES, TERMINALS ON OPPOSITE SURFACES |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.250 INCHES MINIMUM |
ADAQ | BODY LENGTH | 0.520 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.125 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.395 INCHES MAXIMUM |
AEBT | TERMINAL DIAMETER | 0.015 INCHES MINIMUM AND 0.021 INCHES MAXIMUM |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
CQBF | INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP | 10000.0 MEGOHMS |
CQBQ | CAPACITANCE VALUE PER SECTION | 10.000 PICOFARADS SINGLE SECTION |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
CQLZ | III TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS | -200.0 SINGLE SECTION |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 500.0 DC SINGLE SECTION |
CRHD | TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS | -15.0/+15.0 SINGLE SECTION |
CRTP | TOLERANCE RANGE PER SECTION | -1.00/+1.00 PICOFARADS SINGLE SECTION |
CWJK | CASE MATERIAL | PLASTIC |
CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | 100000.0 MEGOHMS |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 0.150 |
CWSG | TERMINAL SURFACE TREATMENT | SOLDER |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
Part 913-0044-000 With Different Manufacturers
913-0044-000
Prominent NSN Parts Brands
- Navistar Canada Inc
- Textron Marine Systems
- Glastic Corp
- C And B Mfg Co
- Moller A P
- Glamox Canada Inc
- Cool Options Inc
- Insultab Inc
- Minco Products Inc
- M B Electronique
- Penn Meter Co
- Ford Werke Gmbh
- Royal Products Inc
- Vetus Llc
- Barry Industries Inc
- Ford Werke Gmbh
- Hart Scientific Llc
- Unimac Corp
- Interphase Inc
- Zamzow Manufacturing Company
- View More
Highly Demanding NSN Components
- Flag Helicopter
- Pump Hauldown
- parts kit test set
- Ferrule Wind Gage
- insert bushing airc
- Stop Droop
- Pump Air Driven
- Operators Panel
- Seal Ring Canopy
- Extracor Card