88-4470 (NSN 5961-01-071-3250) by Powerex Corp - Request an Instant Quote
88-4470 (NSN 5961-01-071-3250, 5961010713250) NSN Information
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5961-01-071-3250 Item Description: Semiconductor Devic | 5961 | 010713250 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | U | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
88-4470 | 5 | 2 | 5 |
NSN 5961-01-071-3250, 5961010713250 Characteristic Data
MRC | Criteria | Characteristic |
---|---|---|
ABBH | INCLOSURE MATERIAL | METAL |
ABHP | OVERALL LENGTH | 1.025 INCHES MINIMUM AND 1.065 INCHES MAXIMUM |
ADAV | OVERALL DIAMETER | 2.100 INCHES MAXIMUM |
AGAV | END ITEM IDENTIFICATION | AN/TPQ-37 AND AN/TPQ-36 FIREFINDER RADAR. |
AXGY | MOUNTING METHOD | PRESS FIT |
CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE |
CTMZ | III SEMICONDUCTOR MATERIAL | SILICON |
CTQN | VOLTAGE RATING IN VOLTS PER CHARACTERISTIC | 750.0 MAXIMUM NONREPETITIVE PEAK REVERSE VOLTAGE, MAXIMUM PEAK TOTAL VALUE AND 650.0 MAXIMUM REPETITIVE PEAK REVERSE VOLTAGE, MAXIMUM PEAK TOTAL VALUE |
CTQX | CURRENT RATING PER CHARACTERISTIC | 700.00 AMPERES FORWARD CURRENT, TOTAL RMS MAXIMUM OF STANDARD RANGE |
CTRD | POWER RATING PER CHARACTERISTIC | 2.0 WATTS SMALL-SIGNAL INPUT POWER, COMMON-COLLECTOR BLANK |
CTSG | MAXIMUM OPERATING TEMP PER MEASUREMENT POINT | 125.0 DEG CELSIUS JUNCTION |
TEST | TEST DATA DOCUMENT | 05869-723097 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
TTQY | TERMINAL TYPE AND QUANTITY | 1 CASE AND 2 UNINSULATED WIRE LEAD W/TERMINAL LUG |
Recently Viewed Parts
Part 88-4470 With Different Manufacturers
88-4470
88-4470
Prominent NSN Parts Brands
- Navistar Canada Inc
- Textron Marine Systems
- Glastic Corp
- C And B Mfg Co
- Moller A P
- Glamox Canada Inc
- Cool Options Inc
- Insultab Inc
- Minco Products Inc
- M B Electronique
- Penn Meter Co
- Ford Werke Gmbh
- Royal Products Inc
- Vetus Llc
- Barry Industries Inc
- Ford Werke Gmbh
- Hart Scientific Llc
- Unimac Corp
- Interphase Inc
- Zamzow Manufacturing Company
- View More
Highly Demanding NSN Components
- Flag Helicopter
- Pump Hauldown
- parts kit test set
- Ferrule Wind Gage
- insert bushing airc
- Stop Droop
- Pump Air Driven
- Operators Panel
- Seal Ring Canopy
- Extracor Card