JA2A3-20-250-2A (NSN 5925-00-863-4232) by Heinemann Electric Co Inc - Request an Instant Quote

JA2A3-20-250-2A Part Details

Part Number : JA2A3-20-250-2A
Alternate P/N : JA2A3202502A
Manufacturer: Heinemann Electric Co Inc
NSN : 5925-00-863-4232
NIIN : 008634232
Item Name : circuit breaker
CAGE Code : L3330
FSC : 5925 Circuit Breakers

Are you looking for a quote on NSN part JA2A3-20-250-2A? If so, please fill out the form. The national stock number (NSN) is 5925008634232, and the JA2A3-20-250-2A part is manufactured by Heinemann Electric Co Inc. Please enter as much detail as possible, this information will help us provide you the best quote.

NSNfulfillment.com is a leading distributor of Heinemann Electric Co Inc hard-to-find NSN parts JA2A3-20-250-2A, military vehicles parts, ground effect vehicles, motor vehicles, trailers, aircraft tire and tubes parts and vehicular equipment and components. NSNfulfillment.com is owned and operated by ASAP Semiconductor, an AS9120B, ISO 9001:2015 company. We stock an enormous inventory of millions of NATO Stock Number parts that are sourced from over 5,000 top manufacturers. All parts are organized in 26 different categories with distinct FSCs.

PRODUCT DETAILS

“*” Symbols for mandatory fields

CONTACT INFORMATION

We will not share your information to any third parties.

   * By clicking this box, I acknowledge that I have read and accept the ASAP Semiconductor Terms and Conditions and agree that all quotes and purchase orders are exclusively subject to the ASAP Semiconductor Terms and Conditions.
  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

NSN Part number JA2A3-20-250-2A possess the Federal Supply Group 5925 Circuit Breakers.

Your quotation will be answered by a member of our experienced sales team. For more details about Heinemann Electric Co Inc part JA2A3-20-250-2A call us on our toll-free number, +1-714-705-4780, we are available 24/7. You can also email your Bill of Materials (BOM) to sales@nsnfulfillment.com to accelerate the buying process.

JA2A3-20-250-2A (NSN 5925-00-863-4232, 5925008634232) NSN Information

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-00-863-4232

Item Description:

Circuit Breaker

59250086342320P
CIICHCCESDPMICCriticalityENAC
U U
Part NumberISCRNVCRNCCHCCMSDSSADC
Ja2a3-20-250-2a295

NSN 5925-00-863-4232, 5925008634232 Characteristic Data

MRCCriteriaCharacteristic
AAQLBODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE
ADAQBODY LENGTH1.985 INCHES MINIMUM AND 2.015 INCHES MAXIMUM
ADATBODY WIDTH1.468 INCHES MINIMUM AND 1.532 INCHES MAXIMUM
ADTVCASE MATERIALPLASTIC
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.655 INCHES MINIMUM AND 1.665 INCHES MAXIMUM
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM
AJECBOSS HEIGHT0.125 INCHES MINIMUM AND 0.135 INCHES MAXIMUM
AKPXPOLE QUANTITY2
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE20.0 AMPERES AC ALL LOCATIONS
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS250.0 AC ALL LOCATIONS
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1000.0 AC ALL LOCATIONS
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY2 TOGGLE
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE AND TWO LINKED
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS
CQJXNOMINAL THREAD SIZE0.138 INCHES
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS
FREQFREQUENCY IN HERTZ60.0 ALL LOCATIONS
THSDTHREAD SERIES DESIGNATORUNC
TTQYTERMINAL TYPE AND QUANTITY4 TAB, SOLDER LUG
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.555 INCHES MINIMUM AND 1.565 INCHES MAXIMUM
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE1.835 INCHES MINIMUM AND 1.845 INCHES MAXIMUM
AXHRMOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
CMLPTHREAD QUANTITY PER INCH32
CPRWACTUATOR FUNCTIONTRIP-RESET
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTPROOF