CD2-A3-U-10-120 240-P (NSN 5925-01-326-5782) by Eaton Corporation - Request an Instant Quote

CD2-A3-U-10-120 240-P Part Details

Part Number : CD2-A3-U-10-120 240-P
Alternate P/N : CD2A3U10120240P
Manufacturer: Eaton Corporation
NSN : 5925-01-326-5782
NIIN : 013265782
Item Name : circuit breaker
CAGE Code : 0AXU3
FSC : 5925 Circuit Breakers

Are you looking for a quote on NSN part CD2-A3-U-10-120 240-P? If so, please fill out the form. The national stock number (NSN) is 5925013265782, and the CD2-A3-U-10-120 240-P part is manufactured by Eaton Corporation. Please enter as much detail as possible, this information will help us provide you the best quote.

NSNfulfillment.com is a leading distributor of Eaton Corporation hard-to-find NSN parts CD2-A3-U-10-120 240-P, military vehicles parts, ground effect vehicles, motor vehicles, trailers, aircraft tire and tubes parts and vehicular equipment and components. NSNfulfillment.com is owned and operated by ASAP Semiconductor, an AS9120B, ISO 9001:2015 company. We stock an enormous inventory of millions of NATO Stock Number parts that are sourced from over 5,000 top manufacturers. All parts are organized in 26 different categories with distinct FSCs.

PRODUCT DETAILS

“*” Symbols for mandatory fields

CONTACT INFORMATION

We will not share your information to any third parties.

   * By clicking this box, I acknowledge that I have read and accept the ASAP Semiconductor Terms and Conditions and agree that all quotes and purchase orders are exclusively subject to the ASAP Semiconductor Terms and Conditions.
  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

NSN Part number CD2-A3-U-10-120 240-P possess the Federal Supply Group 5925 Circuit Breakers.

Your quotation will be answered by a member of our experienced sales team. For more details about Eaton Corporation part CD2-A3-U-10-120 240-P call us on our toll-free number, +1-714-705-4780, we are available 24/7. You can also email your Bill of Materials (BOM) to sales@nsnfulfillment.com to accelerate the buying process.

CD2-A3-U-10-120 240-P (NSN 5925-01-326-5782, 5925013265782) NSN Information

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-01-326-5782

Item Description:

Circuit Breaker

59250132657820P
CIICHCCESDPMICCriticalityENAC
U A
Part NumberISCRNVCRNCCHCCMSDSSADC
Cd2-A3-U-10-120 240-P595

NSN 5925-01-326-5782, 5925013265782 Characteristic Data

MRCCriteriaCharacteristic
ADAQBODY LENGTH5.110 INCHES MINIMUM AND 5.140 INCHES MAXIMUM
ADATBODY WIDTH2.072 INCHES MAXIMUM
ADTVCASE MATERIALPLASTIC
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH3.535 INCHES MINIMUM AND 3.565 INCHES MAXIMUM
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH1.011 INCHES MINIMUM AND 1.041 INCHES MAXIMUM
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.735 INCHES MINIMUM AND 2.765 INCHES MAXIMUM
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.011 INCHES MINIMUM AND 1.041 INCHES MAXIMUM
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJECBOSS HEIGHT0.205 INCHES MINIMUM AND 0.235 INCHES MAXIMUM
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE3.535 INCHES MINIMUM AND 3.565 INCHES MAXIMUM
AKPXPOLE QUANTITY2
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE10.0 AMPERES AC ALL LOCATIONS
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC ALL LOCATIONS
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS7500.0 AC ALL LOCATIONS
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICINSTANTANEOUS ALL LOCATIONS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS
CPRTMANUAL ACTUATOR TYPE AND QUANTITY2 TOGGLE
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE AND TWO LINKED
CQJXNOMINAL THREAD SIZE0.138 INCHES
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTPROOF AND FUNGUS PROOF
THSDTHREAD SERIES DESIGNATORUNC
TTQYTERMINAL TYPE AND QUANTITY4 THREADED STUD
AAQLBODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS
FREQFREQUENCY IN HERTZ50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS