CD5-Z30-1 (NSN 5925-01-330-8678) by Litton Systems Inc - Request an Instant Quote

CD5-Z30-1 Part Details

Part Number : CD5-Z30-1
Alternate P/N : CD5Z301
Manufacturer: Litton Systems Inc
NSN : 5925-01-330-8678
NIIN : 013308678
Item Name : circuit breaker
CAGE Code : 13973
FSC : 5925 Circuit Breakers

Are you looking for a quote on NSN part CD5-Z30-1? If so, please fill out the form. The national stock number (NSN) is 5925013308678, and the CD5-Z30-1 part is manufactured by Litton Systems Inc. Please enter as much detail as possible, this information will help us provide you the best quote.

NSNfulfillment.com is a leading distributor of Litton Systems Inc hard-to-find NSN parts CD5-Z30-1, military vehicles parts, ground effect vehicles, motor vehicles, trailers, aircraft tire and tubes parts and vehicular equipment and components. NSNfulfillment.com is owned and operated by ASAP Semiconductor, an AS9120B, ISO 9001:2015 company. We stock an enormous inventory of millions of NATO Stock Number parts that are sourced from over 5,000 top manufacturers. All parts are organized in 26 different categories with distinct FSCs.

PRODUCT DETAILS

“*” Symbols for mandatory fields

CONTACT INFORMATION

We will not share your information to any third parties.

   * By clicking this box, I acknowledge that I have read and accept the ASAP Semiconductor Terms and Conditions and agree that all quotes and purchase orders are exclusively subject to the ASAP Semiconductor Terms and Conditions.
  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

NSN Part number CD5-Z30-1 possess the Federal Supply Group 5925 Circuit Breakers.

Your quotation will be answered by a member of our experienced sales team. For more details about Litton Systems Inc part CD5-Z30-1 call us on our toll-free number, +1-714-705-4780, we are available 24/7. You can also email your Bill of Materials (BOM) to sales@nsnfulfillment.com to accelerate the buying process.

CD5-Z30-1 (NSN 5925-01-330-8678, 5925013308678) NSN Information

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-01-330-8678

Item Description:

Circuit Breaker

59250133086780P
CIICHCCESDPMICCriticalityENAC
U A
Part NumberISCRNVCRNCCHCCMSDSSADC
Cd5-Z30-1525

NSN 5925-01-330-8678, 5925013308678 Characteristic Data

MRCCriteriaCharacteristic
AAQLBODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE
ABTDMOUNTING SLOT WIDTH0.164 INCHES NOMINAL
ADAQBODY LENGTH4.740 INCHES MINIMUM AND 4.760 INCHES MAXIMUM
ADATBODY WIDTH5.180 INCHES MAXIMUM
ADTVCASE MATERIALPLASTIC
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH3.537 INCHES MINIMUM AND 3.557 INCHES MAXIMUM
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.740 INCHES MINIMUM AND 2.760 INCHES MAXIMUM
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJECBOSS HEIGHT0.209 INCHES MINIMUM AND 0.229 INCHES MAXIMUM
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE3.475 INCHES MINIMUM AND 3.495 INCHES MAXIMUM
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITY10 THREADED HOLE AND 5 SLOT
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE10.0 AMPERES AC FIRST LOCATION
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE10.0 AMPERES AC SECOND LOCATION
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE10.0 AMPERES AC THIRD LOCATION
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE5.0 AMPERES DC FIFTH LOCATION
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE5.0 AMPERES DC FOURTH LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS140.0 DC FOURTH LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC FIRST LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC THIRD LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS5000.0 AC THIRD LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS5000.0 DC FOURTH LOCATION
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP FIFTH LOCATION
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP FOURTH LOCATION
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES/RELAY TRIP FIRST LOCATION
CQQCTRIP RELEASE DUTY CYCLECONTINUOUS FIRST LOCATION
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT20.000 MINIMUM AT 200 PCT THIRD LOCATION AND 100.000 MAXIMUM AT 200 PCT THIRD LOCATION
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT25.000 MINIMUM AT 200 PCT FIFTH LOCATION AND 95.000 MAXIMUM AT 200 PCT FIFTH LOCATION
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT25.000 MINIMUM AT 200 PCT FOURTH LOCATION AND 95.000 MAXIMUM AT 200 PCT FOURTH LOCATION
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDVIBRATION RESISTANT AND SHOCK RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF
FREQFREQUENCY IN HERTZ60.0 FIRST LOCATION
FREQFREQUENCY IN HERTZ60.0 SECOND LOCATION
FREQFREQUENCY IN HERTZ60.0 THIRD LOCATION
TTQYTERMINAL TYPE AND QUANTITY12 THREADED STUD
CMLPTHREAD QUANTITY PER INCH32
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS240.0 AC SECOND LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS5000.0 DC FIFTH LOCATION
CPRKAUXILIARY TRIP COIL VOLTAGE TYPE AND RATING IN VOLTS25.0 DC NOMINAL FIRST LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS140.0 DC FIFTH LOCATION
CPRWACTUATOR FUNCTIONTRIP-RESET
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SECOND LOCATION
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP THIRD LOCATION
CQJXNOMINAL THREAD SIZE0.138 INCHES
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT20.000 MINIMUM AT 200 PCT FIRST LOCATION AND 100.000 MAXIMUM AT 200 PCT FIRST LOCATION
THSDTHREAD SERIES DESIGNATORUNC
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH1.016 INCHES MINIMUM AND 1.036 INCHES MAXIMUM
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.016 INCHES MINIMUM AND 1.036 INCHES MAXIMUM
AKPXPOLE QUANTITY5
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS5000.0 AC FIRST LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS5000.0 AC SECOND LOCATION
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC ALL LOCATIONS
CPRTMANUAL ACTUATOR TYPE AND QUANTITY5 TOGGLE
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, THREE, FOUR, AND FIVE LINKED
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT20.000 MINIMUM AT 200 PCT SECOND LOCATION AND 100.000 MAXIMUM AT 200 PCT SECOND LOCATION
FEATSPECIAL FEATURESFULL LENGTH BARRIERS BETWEEN POLES INCLUDED