5925-01-150-4464, 5925011504464 (Circuit Breaker) - National Stock Number Lookup

NSN 5925-01-150-4464 of part number 201035, 201035, 3088-50, 3088-50 by the manufacturer, Cole Hersee Company, Wiggins Lift Co Inc is in stock and ready to ship out. We make NSN parts purchasing as simple as possible. We list corresponding components such as 5925-01-150-4464 so that you can make the purchasing decision that is right for you. Our dedicated team are on hand to help source any-hard-find NSN parts or answer any procurement questions. We only source from manufacturers we trust and are the only independent distributor with a NO CHINA SOURCING policy. Unlike other companies, we pair every customer with a dedicated account manager. We respond to all RFQs within 15 minutes. Submit an RFQ today to get started.

5925-01-150-4464 NSN Information

Alternative NSN: 5925-01-150-4464
Item Name: Circuit Breaker
FSG: 59 Electrical and Electronic Equipment Components
Federal Supply Class (FSC): 5925 Circuit Breakers
NIIN: 011504464
NCB Code: USA (01)
Manufacturers: Cole Hersee Company, Wiggins Lift Co Inc

NSN 5925-01-150-4464 Manufacturing Part Numbers

Part No Manufacturer Item Name QTY RFQ
201035 wiggins lift co inc circuit breaker Avl RFQ
201035 cole hersee company circuit breaker Avl RFQ
3088-50 wiggins lift co inc circuit breaker Avl RFQ
3088-50 cole hersee company circuit breaker Avl RFQ

Product Specification of NSN 5925011504464

MRCCriteriaCharacteristic
AAQLBODY STYLERECTANGULAR DIMENSIONAL ENVELOPE
ABHPOVERALL LENGTH1.990 INCHES MINIMUM AND 2.010 INCHES MAXIMUM
ABKWOVERALL HEIGHT1.365 INCHES MINIMUM AND 1.385 INCHES MAXIMUM
ABMKOVERALL WIDTH1.740 INCHES MINIMUM AND 1.760 INCHES MAXIMUM
ADTVCASE MATERIALMETAL
AEBVUNTHREADED MOUNTING HOLE DIAMETER0.210 INCHES MINIMUM AND 0.230 INCHES MAXIMUM
AFJNFRAGILITY FACTORMODERATELY RUGGED
AKPXPOLE QUANTITY2
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
BBRJSPECIAL HANDLING FEATUREMAGNETIC
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE50.0 AMPERES DC ALL LOCATIONS
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS24.0 DC ALL LOCATIONS
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1000.0 DC ALL LOCATIONS
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRJTRIP RELEASE METHODTHERMAL ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICINSTANTANEOUS ALL LOCATIONS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS
CPRQRESET METHODAUTOMATIC
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDHERMETICALLY SEALED
CRCFTRIP RELEASE AMBIENT TEMP RATING25.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TTQYTERMINAL TYPE AND QUANTITY4 THREADED STUD

NSN 5925-01-150-4464 - Similar National Stock Numbers

Get an Estimate for Your Required Component

You will receive a response in 15 minutes or less









Install ASAP App for Quick Actions